World-Map
 

U181, U187, U189

Energy Meters for 4 Quadrants, 2 Tariffs, Calibrated

The calibrated, compact energy meters included in our Compact Line product range can be used to acquire and bill active energy in industrial, household, commercial and building management applications.

Relevant values are transmitted to data logging, billing and optimizing systems, as well as to building automation and control technology applications, by means of 2 pulse outputs or the integrated infrared interface and an external interface module. Modbus, M-Bus and Ethernet are currently supported.

/ /
Two S0 Pulse Outputs

The meter also measures all of the electrical system’s essential parameters and makes them available via the infrared interface. Energy and instantaneous power values appear directly at the display.

  • Compact, double-tariff energy meter for 4 quadrants, import and export, partial and aggregate meter and up to 30 measured values for real-time quantities
  • Variants for 2 and 4-wire-systems with 80 A direct-connection, or 1A and 5A transformer connection
  • Programmable current transformer ratio of 1 to 10000 and additionally displayable secondary value for energy
  • Double-tariff measurement with input for tariff switching
  • Partial meter can be started, stopped and reset
  • Active energy measurement per EN50470-3, class B, for industrial and commercial applications, as well as demanding household applications
  • Cost savings thanks to initial calibration at the factory in accordance with MID, conformity assessment procedure modules B and D
  • Reactive energy measurement per EN 62053-23, class 2
  • Phase sequence indicator and error detection for violation of voltage, current and frequency measuring ranges
  • 2 programmable pulse outputs for energy values
  • Flexible communication via infrared interface and optional interface modules for M-Bus, Modbus and Ethernet
  • Large LCD panel with background illumination
  • Tamper-proof covers, configuration disabling
  • 3 year guarantee
  • Made in EU
     
    Energy Meters
System Voltage -
Output of reactive energy (varh)
via display and interface
For 
direct connection, 
80 A
For transformer 
connection, 
1 (6) A and 5 (6) A
2-wire  230 to 240 V, 50 / 60 Hz U181A -
4-wire 3 x 230 / 400 to 240 / 415 V, 50 / 60 Hz U189A U189B
  --- not available anymore --- U187A U187B
  --- not available anymore --- U18xD U18xW

 
See accessories below for optional interface modules.

 

  Article No: U181A U189A U189B
Icon Technical Data » GB » F » I (pdf 235 kB)
Icon Operating Instructions U181 » D-GB » F-I
Icon Operating Instructions U187-189 A,D » D-GB » F-I
Icon Operating Instructions U187-189 B,W » D-GB » F-I
Icon Pamphlet » GB » NL (pdf 1234 kB)
EC Type Approval U181A - MID Module B (pdf 1254 kB)
EC Type Approval U189A - MID Module B (pdf 1337 kB)
EC Type Approval U189B - MID Module B (pdf 1340 kB)
EC Quality Management System - MID Module D (pdf 517 kB)
CE Certification (pdf 46 kB)
Software SMARTCOLLECT
Software EMC 5.x
Accessories (display)