Current Probes

and Current Transformer Clamps - for Universal Current Measurements

  • Application: universal current measurements
  • Connector: 4 mm safety banana plugs
  • Output: voltage e.g. current
    Current Transformer Clamps -> Current Output mA/A
    Current Sensor Clamps -> Voltage Output mV/A

Current Clamp Meters with Display - click here     
Current Probes and Current Sensors - for Power Analyzers - here     

AC-/DC Current Sensors
- Voltage Output
Type Nom.Current
A DC ;AC
CAT
@..V
Cross
Ø mm
Sensitivity Frequency
Range
Intrinsic Error
±(% v.M.+mA)
Article
No.
z201awith Battery
 30h
 
 30h
 
 30h
CP30 0.. 30 A
0.. 30 A peak
III
300
25 100 mV/A DC..20kHz
(-1dB)
1% *0,002A Z201B
CP330 0.. 30 A
0.. 300 A
III
300
25 10 mV/A
1  mV/A
DC..20kHz
(-3dB)
1% +0,05A
1% +0,1A
Z202B
CP1100 0..100 A 
0..1000 A
III
300
32 10 mV/A
1 mV/A
DC..20kHz
(-1dB)
1% +0,05A
1% *0,1A
Z203B
CP1800 0..125 A 
0..1800 A
III
300
32 10 mV/A
1 mV/A
DC..20kHz
(-1dB)
1% +0,05A
1% *0,1A
Z203B
xxwith Batt.
 50h
Z13B 0,5..60/600A
0,2..40/400A~
III
300
50 10 mV/A
1  mV/A
DC..65Hz
..10kHz
1,5%
2%
Z213B
AC Current Sensors
- Voltage Output
Type   Nom.Current
A AC
CAT
@..V
Cross
Ø mm.
Sensitivity Frequency
Range
Intrinsic Error
±(% v.M.+mA)
Article
No.
TT WZ11B 0,5-20
5-200
III
600
20 100mV/A
10mV/A
30..48..65
..500Hz
1.. 3% Z208B
WZ12B 0,01-100 III
300
15 0,1 mV/mA 45..65
..500Hz
1,5% +1 mA Z219B
WZ12C 0,001-15
1-150
III
300
15 1mV/mA
1mV/A
48..65
..500Hz
3% +0,15mA
2%+0,1mA
Z219C
WZ12E 0,2-150   15 10 mV/A   2% +10 mA Z823D
WZ12F 0,02-15   15 100 mV/A   2% +1mA Z823E
Clip 0100S 0,001-15
1-150
  15 1mV/mA
1mV/A
  3% +0,15mA
2%+0,1mA
Z501E
3512 Z3512A 0,001-1/10/
/100/1000
 
III
600
52 1000/100
/10/1 mV/A
10..48..65
..3kHz
0,2%.. 0,7%   Z225A
  Z821B 1-3000   64 0,33mV/A   0,5% +0,5 mV Z821B
METRAFLEX 300M 3 A
30 A
300 A
III @
1000
IV @
600
50 1 V/A
100 mV/A
10 mV/A
20 Hz
...100 kHz
1% +0,2 A
1% +0,2 A
1% +1 A
Z207M
METRAFLEX P300 3 A
30 A
300 A
III
1000
IV
600
140 1 V/A
100 mV/A
10 mV/A
20 Hz
...4 kHz
1% +0,01 A
1% +0,1 A
1% +1 A
Z502E
METRAFLEX 3000 30 A
300 A
3000 A
III @
1000
IV @
600
200 100mV/A
10 mV/A
1 mV/A
10 Hz
... 20 kHz
1% +0,1 A
1% +0,1 A
1% + 1 A
Z207E
AC Current Transformers
- Current Output
Type Nom.Current
A AC
CAT
@..V
Cross
Ø mm
Sensitivity
mV/A  
Frequency
Range
Intrinsic Error
±(%v.VAusg+mV)
Article
No.
T WZ12A 15.. 180 III
300
15 1mA/A 45..65
..400Hz
3% Z219A
WZ12D 0,03-150 III
300
15 1mA/A 45..65
..500Hz
2,5% +1mA Z219D  
T3511 WZ11A 1.. 200 III
600
20 1mA/A 48..65
..400Hz
1.. 3% Z208A
Z3511 4-500 III
600
30x63 1mA/A 45..65 
..1kHz
3% +0,4 A GTZ3511­000R0001
35123514 Z3512 0,5-1000 III
600
52 1mA/A 30..45..65
..5kHz
0,5%.. 0,7% GTZ3512­000R0001
Z3514 1-2000 III
600
64 1mA/A 30..45..65
..5kHz
0,5% GTZ3514­000R0001